RVS-DX
Standard Duty Soft Starter with built-in bypass Ratings: 8-170A, 208-600V
Advanced Features:
- Superior soft starting and soft stopping
- Comprehensive motor protection
- RS 485 Modbus communications
- Frequency autotracking 45-65Hz
- User friendly
- Line or inside delta connection
- Current limit
- Unique pump control software
- Torque and current control
- Dual adjustment
- Slow speed with reversing
- Pulse start
Standard Duty Combination Starter package with built in:
- Circuit breaker, rotary handle
- Shunt rated bypass
- Start/stop/reset pushbuttons
- Power On, Run, Fault Lights
- HOA switch
- CPT
- NEMA 4/12 enclosure
Other enclosures and accessories available.
The RVS-DX incorporates enhanced soft start/soft stop characteristics, motor protection features with built-in bypass in a compact design suitable for pumps, fans and other industrial applications.
Protection Features:
- Too many starts
- Long start time (Stall)
- Shear-pin (Start + Run + Jam)
- Electronic overload
- Under current
- Phase loss and sequence
- Under, over and no voltage
- Load loss
- Shorted SCR
- Starter over-temperature
- External fault
Digital Controller:
- LCD – 2 lines x 16 characters
- Selectable languages: English, German, French and Spanish
- Four LEDs: On, Run, Ramp Up/Down and Fault
- Statistical Data
- Full description parameter settings
RVS-DXM
General Duty Soft Starter with built-in bypass Ratings: 210 - 1100A, 208-600V
Advanced Features:
- General duty rated with built-in bypass
- Ambient operating temp −10 to +/−50°C
- Comprehensive motor protection
- RS 485 Modbus communications
- Frequency autotracking 45-65Hz
- User friendly
- Line or inside delta connection
- Current limit
- Unique pump control software
- Torque and current control
- Dual adjustment
- Slow speed with reversing
- Pulse start
RVS-DX & RVS-DXM
Combination Starter packages with built in:
- Circuit breaker, rotary handle
- Shunt rated bypass
- Start/stop/reset pushbuttons
- Power On, Run, Fault Lights
- HOA switch
- CPT
- NEMA 4/12 enclosure
Other enclosures and accessories available.
The RVS-DXM incorporates enhanced soft start/soft stop characteristics, motor protection features with built-in bypass in a compact design suitable for nearly any application.
Protection Features and Digital Controller
- Comprehensive, built-in motor protection (same as RVS-DX)
- Multi-language, 2-line x 16 character display
- Four LEDs (On, Run, Ramp Up/Down and Fault
- Statistical Data
- Full Description parameter settings
- Remote keypad option
Flexibility by Design:
- Line and Load Connections
Choose from six bus bars (top and bottom) for flexible installation - Rated: 350% for 30 seconds;
std. 65kAIC (breaker), 100kAIC (fuses) - Two models to choose from:
- 400 = 208 – 400V
- 600 = 440 – 600V
RVS-DN
Heavy Duty Soft Starter Ratings: 8-3000A, 230-1200V
- Complete line 8-3000A, 230-1200V
- Heavy duty, fully rated design
- Busbar provisions for adding external bypass contactor
- Superior starting and stopping
- Comprehensive motor protection
- RS 485 Modbus communications
- Frequency autotracking 45-65Hz
- Line or inside delta connection
- Ambient temperature rating 50°C
- Unique pump control software
- Torque and current control
- Dual adjustments
- Slow speed with reversing
- Pulse start
Heavy Duty Combination Starter with built in:
- Circuit breaker with flange handle
- ATL rated bypass
- Electronic O/L relay for emergency start protection
- Control Power Transformer
- SS/ATL switch
- Start/stop/reset pushbuttons
- Local/Off/Remote switch
- Run, Fault, Power On lights
- NEMA 4/12 enclosure
Other enclosures and accessories available.
A heavy duty, full featured digital soft starter, incorporating superior soft start/soft stop control for the most demanding applications. Comprehensive motor protection package and the robust design ensures long term, reliable performance.
Protection Features:
- Too many starts
- Long start time (Stall)
- Shear-pin (Start + Run + Jam)
- Electronic overload
- Under current with delays
- Phase loss and sequence
- Under, over and no voltage
- Load loss
- Shorted SCR
- Starter over-temperature
Digital Controller Marine Type Test Certifications:
- LCD – 2 lines x 16 characters
- Selectable languages: English, German, French and Spanish
- Two display modes: basic and advanced
- Statistical Data
- Eight LEDs for status indication available upon request
RVS-AX
Analog Soft Starter Ratings: 8-170A, 230-600V
A three phase soft starter with integral bypass and built-in motor protection, all in a low cost, compact package. Easy to install, easy to operate, the RVS-AX is a cost effective solution for soft starting small and medium size motors in standard duty applications.
Performance Features:
- Soft start and soft stop
- Integral bypass (except 8A and 17A models)
- Current limit
- Built-in motor protection (electronic O/L, phase loss and starter over-temp)
- Start / Stop voltage free contact
- Aux relays (8A, 250VAC)
- End of acceleration relay
- Fault relay
LED Display:
- Power on
- Ramp Up / Down
- Run
- Overload
- Phase Loss
- Over Temperature
SOLBRAKE
DC Injection Brake Ratings: 10-390A, 230 - 690V
- Reduced stopping time:
- Increases production rate in machine tools and high inertia loads
- Increases safety of hazardous machines
- Soft, smooth stopping prevents wear and tear of mechanical parts
- Adjustable braking torque, matching load size and required stop time
- Auto stop eliminates excessive motor heating
- Maintenance free, highly reliable operation
- Easy installation
Applications:
- Machine tools
- Circular saws
- Stopping high inertia loads
- Safety brakes
- Large flywheel applications
Standard Ratings:
The Solbrake should be selected according to the motor’s nominal current and starting conditions. For severe duty applications it is recommended that you select the next higher amperage rated unit.
The Solbrake Electronic brake provides fast, smooth, frictionless braking of standard three phase AC motors by injecting controlled DC current into the motor windings after the line contactor has opened. This DC current induces a stationary magnetic field which exerts a braking torque on the rotor. The Solbrake is an ideal replacement for old electro-mechanical braking systems including reversing or regenerative braking.
Settings:
- Braking Torque – Determines the DC current level injected into the motor windings
- Two operation modes:
- Auto Mode: DC Injection automatically ends when motor stops
- Manual Mode: DC Injection ends after a pre-set braking time. This mode can be used to briefly “hold” the load at stand still.
HRVS-TX
Eliminating Transformer Inrush Current. Transformer Soft-Starter, for every type of transformer in Low and Medium Voltage, Up to 30MVA at 15kV
The HRVS-TX is the ideal soft-starting solution for medium and low voltage transformers. The sophisticated control ensures the elimination of the magnetizing inrush current, thus, eliminates nuisance tripping as well as dynamic shock to the transformer windings. The starter can be supplied as IP31-67, NEMA 1-6X with options such as Line and Bypass vacuum contactors or circuit breakers, is connect switches, main and control protection fuses, transformer protection relay, etc.
Advantages:
- TSR-6 Control and protection relay-the only relay of its kind
- Heavy duty design at 50°C ambient temperature
- Reduced inrush current and dynamic shock
- Applicable models for any transformer
- Optional protection package provides many features
- Transformer heat protection relay – optional
- Communication – RS485 Modbus
- Unique starting characteristics
- User friendly, easy setup and operation
- IP31-standard, higher protection by special order
- Phase shift transformer starting, unique technology
- Advanced “wireless” Electronic Potential Transformer (optional)
- Fault indication to each individual fuse
- Each transformer starter is tested for Partial Discharge (Korona)
- Wide 40-70Hz range for fluctuating frequency systems
- Available as stand alone or Integratable with Solcon’s HRVS-DN medium and low voltage soft starters
Standard & Special Transformers:
- Standard: Oil, Dry, Molded, etc.
- Special: Multi-pole and phase shift
Ratings:
- Maximum Ratings 30MVA, 15kV
Temperature:
- Operating -10° to 50°C
- Storage -20° to 70°C
- Electrical safety-Council Directive