Hyundai Premium Efficiency Motors
Rigid Base
- 1-250 HP
- 3600, 1800 and 1200 RPM
- 208-230/460 volt (1-125 HP)
- 460 volt (150-250 HP)
- TEFC enclosure
- Dual rated service factor – 1.15 for 40°C / 1.0 for 65°C
- Class F insulation
- Rigid base
- Premium efficiency, meets or exceeds EISA 2007 requirements defined in NEMA MG-1 table 12-12
- 5 year warranty
- NEMA Design B
- Cast iron frame and conduit box
- Suitable for part winding start on low voltage (1-125 HP)
- Suitable for wye-delta start (15-250 HP)
- Inverter ready, 10:1 CT / 20:1 VT
- Double drilled feet to accommodate mounting flexibility (324T-449T)
- F2 field mountable
- Class I, Division 2, Groups A, B, C, D
- CC #038A
C-Face – Rigid Base
- 1-200 HP
- 3600, 1800 and 1200 RPM
- 208-230/460 volt (1-125 HP)
- 460 volt (150-200 HP)
- TEFC enclosure
- Dual rated service factor – 1.15 for 40°C / 1.0 for 65°C
- Class F insulation
- C-face – rigid base
- Premium efficiency, meets or exceeds EISA 2007 requirements defined in NEMA MG-1 table 12-12
- 5 year warranty
- NEMA Design B
- Cast iron frame and conduit box
- Suitable for part winding start on low voltage (1-125 HP)
- Suitable for wye-delta start (15-200 HP)
- Inverter ready 10:1 CT / 20:1 VT
- Double drilled feet to accommodate mounting flexibility (324TC-449TC)
- F2 field mountable
- Class I, Division 2, Groups A, B, C, D
- CC #038A
C-Face – Round Body
- 1-40 HP
- 1800 RPM
- 208-230/460 volt
- TEFC enclosure
- Dual rated service factor – 1.15 for 40°C / 1.0 for 65°C
- Class F insulation
- C-face – round body
- Premium efficiency, meets or exceeds EISA 2007 requirements defined in NEMA MG-1 table 12-12
- 5 year warranty
- NEMA Design B
- Cast iron frame and conduit box
- Suitable for part winding start on low voltage (1-40 HP)
- Suitable for wye-delta start (15-40 HP)
- Inverter ready, 10:1 CT / 20:1 VT
- F2 field mountable
- Class I, Division 2, Groups A, B, C, D
- CC #038A
Hyundai IEEE-841 Motors
Rigid Base
- 1 – 250 HP
- 3600, 1800 and 1200 RPM
- Single voltage, 460 volts
- TEFC enclosure
- Dual rated service factor – 1.15 for 40°C / 1.0 for 65°C
- Class F insulation with Class N varnish
- Rigid base
- Full compliance with IEEE-841, version 2009
- Meets or exceeds EISA 2007 efficiency requirement defined in NEMA MG-1 table 12-12
- Parker Hannifin ProTech IP66 labyrinth seals on both drive-end and opposite drive-end bearings
- CSA Certified for Class I, Division II, Groups A, B, C, D
- Inverter duty, 10:1 CT / 1000:1 VT
- Inverter shield insulation and inverter grade magnet wire meets or exceeds NEMA MG-1 Part 31 for exceptional corona and transient protection
- Class B temperature rise
- IP55 degree of protection
- NEMA design B torque
- IEEE-841 motor test report supplied with each motor
- 5 year warranty
C-Face - Rigid Base
- 1 – 100 HP
- 3600 and 1800 RPM
- Single voltage, 460 volts
- TEFC enclosure
- Dual rated service factor – 1.15 for 40°C / 1.0 for 65°C
- Class F insulation with Class N varnish
- C-face – rigid base
- Full compliance with IEEE-841, version 2009
- Meets or exceeds EISA 2007 efficiency requirements defined in NEMA MG-1 table 12-12
- Parker Hannifin ProTech IP66 labyrinth seals on both drive-end and opposite drive-end bearings
- CSA Certified for Class I, Division II, Groups A, B, C, D
- Inverter duty, 10:1 CT / 1000:1 VT
- Inverter shield insulation and inverter grade magnet wire meets or exceeds NEMA MG-1 Part 31 for exceptional corona and transient protection
- Class B temperature rise
- IP55 degree of protection
- NEMA design B torque
- IEEE-841 motor test report supplied with each motor
- 5 year warranty
Hyundai Explosion Proof Motors
Rigid Base
- 1-250 HP
- 3600, 1800 and 1200 RPM
- 208-230/460 volt (1-125 HP)
- 460 volt (150-250 HP)
- TEXP enclosure
- 1.15 service factor
- Class F insulation
- Class B temperature rise
- Rigid base
- Premium Efficiency, meets or exceeds EISA 2007 requirements defined in NEMA MG-1 table 12-12
- 5 year warranty
- NEMA design B
- Cast iron frame and conduit box
- Suitable for part winding start on low voltage (1-125 HP)
- Suitable for wye-delta start (15-250 HP)
- Unique multiple rating system for 40° and 55°C ambient
- 143T-215T: T2C at 40°C, T2B at 55°C, T4 when thermostat is connected
- 254T-286T: T2D at 40°C, T2C at 55°C, T4 when thermostat is connected
- 324T-444T: T3 at 40°C, T2D at 55°C, T4 when thermostat is connected
- 445T-449T: T3 at 40°C, T2D at 55°C, T4 when thermostat connected and 1.0 SF
- Class I, Division 1, Groups C & D, UL Certification
- CC #038A
- CSA Energy Certified
C-Face
- 2-100 HP, 1800 RPM
- 75-100 HP, 3600 RPM
- 208-230/460 volt
- TEXP enclosure
- 1.15 service factor
- Class F insulation
- Class B temperature rise
- C-face – rigid base
- Premium Efficiency, meets or exceeds EISA 2007 requirements defined in NEMA MG-1 table 12-12
- 5 year warranty
- NEMA design B
- Cast iron frame and conduit box
- Suitable for part winding start on low voltage
- Suitable for wye-delta start (15-100 HP)
- Unique multiple rating system for 40° and 55°C ambient
- 143T-215T: T2C at 40°C, T2B at 55°C, T4 when thermostat is connected
- 254T-286T: T2D at 40°C, T2C at 55°C, T4 when thermostat is connected
- 324T-444T: T3 at 40°C, T2D at 55°C, T4 when thermostat is connected
- 445T-449T: T3 at 40°C, T2D at 55°C, T4 when thermostat connected and 1.0 SF
- Class I, Division 1, Groups C & D, UL Certification
- CC #038A
- CSA Energy Certified
Hyundai Severe Duty Large Frame Motors
- 250-600 HP
- 3600, 1800 and 1200 RPM
- Single voltage, 460 volt
- Dual frequency rated 50/60 HZ nameplate
- TEFC enclosure
- IP55 degree of protection
- Class F insulation
- Class B temperature rise
- Rigid base
- Premium efficiency
- 3 year warranty
- Cast iron frame and conduit box
- Heavy rolled steel fan cover
- Ground lug in terminal box
- Cast iron inner bearing caps
- Double drilled feet
- Bi-directional for 1800 and 1200 RPM ratings
- Uni-directional (CCW) for 3600 RPM ratings, each motor shipped with extra fan for directional change
- CSA Certified for Class I, Division 2, Groups A, B, C, D
- Inverter ready, 10:1 CT / 20:1 VT
- Inverter shield insulation and inverter grade magnet wire meets or exceeds • NEMA MG1 Part 31 for exceptional corona and transient protection